A connected industrial machine whose data line passes through a gated segmented wall to a cloud, representing a machine builder's IIoT link treated as a controlled supplier conduit

IIoT Predictive Maintenance Under NIS2: Treat Your Machine Builder’s Cloud Link as a Supplier Conduit — Art. 21(2)(d) Duties and Your Data Act Rights

In short

  • For IIoT security under NIS2, treat the machine builder’s cloud link as a supplier connection under Article 21(2)(d).
  • Split it into telemetry out, commands or updates in, and remote sessions. Only the last two can change the machine.
  • The Data Act gives you access to raw and pre-processed product data and limits how the data holder may use it.
  • Checked against: Directive (EU) 2022/2555, Implementing Regulation (EU) 2024/2690, Regulation (EU) 2023/2854.

Pull a month of firewall logs for the network your newest machine sits on and look for its edge gateway. If that gateway keeps a session open to the machine builder’s cloud day and night, you have found a supplier connection that nobody approved through an access request. Many predictive-maintenance offers work this way. A box on the machine sends vibration, temperature and run-time data out, and the builder’s platform sends back alerts, parameter changes or firmware.

Under NIS2 that link belongs in your supply chain file. Article 21(2)(d) of Directive (EU) 2022/2555 covers “the relationships between each entity and its direct suppliers or service providers”. Article 21(3) asks you to take into account “the vulnerabilities specific to each direct supplier and service provider”. The practical way to meet both is to treat the link as a conduit: a defined path between your zones and a system someone else operates, with a known direction, content and owner.

Does This Apply to Your Plant?

In plain terms: if your organisation is an essential or important entity under national NIS2 law and any of your machines talks to its maker, Article 21 covers that connection. The detailed EU checklist for it, Implementing Regulation 2024/2690, binds only digital providers. Everyone else can use it as a benchmark.

Free Download

Get the NIS2 Article 21 Compliance Checklist

90+ assessment items mapped to CIR 2024/2690 — instant PDF, no payment.

✓ Check your inbox — the PDF is on its way.

Your position What binds you How to use this guide
Manufacturer in NIS2 Annex II, sector 5 (for example NACE C28, machinery and equipment), in scope under national law Article 21 of the Directive, through your national law Use the Implementing Regulation points below as a benchmark and record why you depart from them
Other essential or important entity running maker-connected equipment (food, chemicals, water) Same Same
Digital provider listed in Article 1 of the Implementing Regulation (for example a managed service provider) Article 21 plus the Implementing Regulation’s Annex Apply the points directly; Article 2(2) makes you document any “where appropriate” point you skip
The machine builder offering the service Depends on its own sector and size, plus the Machinery Regulation and the Data Act See “Who Owns Which Risk” below

Two points settle the scope question. First, the machine’s controller is itself in scope as an asset. Article 6(1)(b) of the Directive defines a network and information system as “any device or group of interconnected or related devices, one or more of which, pursuant to a programme, carry out automatic processing of digital data”. A PLC with a gateway meets that definition, whoever operates the gateway. Second, Implementing Regulation (EU) 2024/2690 lists the entities it binds in Article 1: DNS, cloud, data centre, managed service and other digital providers. A machinery manufacturer that uses connected machines is not on that list. ENISA’s implementation guidance says its content “may be considered useful by other public or private bodies”. We cite the Annex points in that spirit, as the most detailed EU text on what Article 21(2) means in practice.

One Link, Three Channels: Classify Before You Secure

The single most useful step is to stop treating “the IIoT connection” as one thing. Each maker-connected machine can carry up to three channels, and only two of them can change what the machine does. NIST SP 800-82r3 makes the same distinction: IIoT devices “may support a separate data monitoring (i.e., read-only capability)” with minimal impact on operational controls or safety, “which may allow organizations to implement security operations differently”.

Channel Direction Can it change the machine? Benchmark points (Reg. 2024/2690 Annex) Default control
1. Telemetry: sensor values, alarms, run hours Out No, if it is read-only 6.7.2(c), 6.7.2(i), 6.8.1 Permanent, outbound only, to fixed destinations, documented as required communication
2. Commands and updates: parameter sets, firmware, recipes In Yes 6.7.2(h), 5.1.4(f), 11.2.2(d) Approved per change, with an expiry, logged
3. Interactive service session: technician remote desktop, PLC programming In Yes 6.7.2(d), 6.7.2(h), 11.3.2(a), 11.5.2(b) Per request, time-limited, named person, multi-factor authentication

The trap is the firewall view. A rule that only allows connections opened from inside does not make a channel read-only. Once the gateway has opened a session to the cloud, data and commands can travel back down it. So the classification has to come from what the gateway and the cloud service can do, not from the direction of the first packet. Ask the builder in writing which of the three channels its service uses and whether the gateway can write to the controller. If the answer is “telemetry only”, get that stated in the contract, because it decides how much of the next section applies.

Segmentation: Put the Builder’s Box in Its Own Zone

For a CISO or OT lead, the segmentation answer is short: the gateway is a third party’s system on your premises, and the benchmark text says so plainly. Point 6.8.1 of the Annex states: “They shall segment their systems and networks from third parties’ systems and networks.” Point 6.8.2 adds that systems critical to operation or to safety sit in secured zones (c), that a demilitarised zone protects communication into and out of your networks (d), and that traffic between and within zones is restricted to what operation or safety needs (e).

NIST shows what that looks like for IIoT. Its example architecture in section 5.4.2 “shows separate network segments for supporting the additional IIoT components”, with traffic from the IIoT platform “routed through the DMZ border firewall”. That placement also lets the monitoring tools in the DMZ watch the IIoT tier. In practice, four rules follow:

  • The gateway sits in its own zone, never with one network card on the machine network and another on the internet, bypassing the DMZ.
  • Outbound traffic goes only to the builder’s documented endpoints. Point 6.7.2(f) asks you to “explicitly forbid or deactivate unneeded connections and services”.
  • The channel to the cloud is encrypted and authenticated at both ends. Point 6.7.2(i) describes trusted channels that “provide assured identification of their end points and protection of the channel data from modification or disclosure”.
  • The network diagram shows the conduit all the way to the builder’s cloud. Point 6.7.2(a) asks for network architecture documented “in a comprehensible and up to date manner”.

Where the gateway sits in a Purdue-model layout, and how the DMZ between levels 3 and 4 is built, is covered in our OT and SCADA security guide and our IT/OT convergence guide.

Supplier Access: The Always-On Link Meets the Time Limit

Here the IIoT model and the benchmark text pull in opposite directions. Point 6.7.2(h) says to “allow connections of service providers only after an authorisation request and for a set time period, such as the duration of a maintenance operation”. A predictive-maintenance gateway is designed to stay connected.

Our reading resolves the conflict by channel. A telemetry stream that cannot reach into the machine is a communication your operation needs, which 6.7.2(c) allows. It does not hand the provider access, so it can run permanently once you have documented it. The command and session channels are the provider’s access, and that is where 6.7.2(h) applies. Point 11.2.2(d) points the same way: third-party access rights are limited “in scope and in duration”. NIST’s remote access guidance in section 6.2.10 adds that remote access “should not circumvent or negate safety or security controls” and suggests “automatic timers for removing access”. ENISA’s guidance on network security puts it in one line: “Approve, log and perform remote maintenance of network and information systems in a manner that prevents unauthorised access.”

Identity is the other half. Point 11.5.2 asks for “unique identities for network and information systems and their users” (a) and for each user identity to be linked “to a single person” (b). For an IIoT service, that means:

  • Each gateway has its own credential or certificate, never one shared across the builder’s whole fleet.
  • Each of the builder’s technicians logs in under a named account. A shared “service” login is allowed under 11.5.3 only with explicit approval and documentation.
  • Accounts that can program a controller count as privileged, and 11.3.2(a) expects strong authentication “such as multi-factor authentication” for them.

If you decide a point does not fit, write down why. Article 2(2) of the Implementing Regulation makes that a duty for the entities it binds. For everyone else it is the record an auditor will ask for. How a chemicals site handles interactive DCS vendor sessions is in our chemicals supply chain guide.

The Contract and the Register: What to Ask the Builder For

For procurement and legal teams, point 5.1.4 of the Annex lists what supplier contracts should specify, “where appropriate”. Read against a predictive-maintenance subscription, the clauses become concrete:

Point 5.1.4 What it means for an IIoT service
(a) Cybersecurity requirements Channel classification, encryption, fixed endpoints, gateway hardening
(d) Incident notification “without undue delay” Incidents on the builder’s cloud platform or on its fleet of gateways, not only on your site
(e) Right to audit or to receive audit reports Audit reports for the cloud platform that holds your machine data
(f) Handling vulnerabilities Firmware fixes for the gateway and the controller interface it uses
(g) Subcontracting The builder’s cloud host and any analytics partner who sees your data
(h) Termination: “retrieval and disposal of the information obtained” What happens to years of your machine data when the subscription ends

Point 5.2 then asks for a registry of direct suppliers with contact points and “a list of ICT products, ICT services, and ICT processes” each one provides. For a connected machine that is at least three entries: the gateway, the cloud service and any app your staff use. Ready-made wording for these clauses is in our guide to NIS2 vendor contract clauses.

The Data Act: Rights You Can Use in the Supplier File

In plain terms: the Data Act, Regulation (EU) 2023/2854, is not a cybersecurity law. But it gives the user of a connected machine rights that answer several NIS2 supplier questions for you. It has applied since 12 September 2025.

12 September 2026 Connected products and related services placed on the market after this date must be designed so that their data is accessible to the user by default, easily and securely (Data Act Article 3(1), applied by Article 50).

Source: Regulation (EU) 2023/2854, Articles 3 and 50

Pre-contract information feeds your register. Before you buy or lease a connected product, Article 3(2)(c) requires the seller to say whether it stores data on the device or “on a remote server”, with the retention period. Before a related service is contracted, Article 3(3) requires the provider to state whether it uses the data itself and for what purposes (c), and its identity “and, where applicable, of other data processing parties” (d). Those answers feed your 5.2 registry entry and the subcontracting clauses under 5.1.4(g), and the builder has to supply them.

You can get the raw data, probably not the prediction. Article 4(1) requires data holders to make readily available data accessible to the user free of charge and, where relevant and technically feasible, continuously and in real time. The Commission’s Data Act FAQ (version 1.4) puts raw and pre-processed data in scope, with examples such as “temperature, pressure, flow rate” and “acceleration”. It puts “inferred or derived data” from “proprietary, complex algorithms” out of scope. So vibration readings are likely yours on request. The builder’s failure forecast is likely not.

The builder’s own use of your data is limited. Under Article 4(13), a data holder may use non-personal readily available data only “on the basis of a contract with the user”. It must not use it to derive insights about the user’s “economic situation, assets and production methods” in a way that could undermine the user’s commercial position. Article 4(14) bars passing non-personal product data to third parties beyond fulfilling that contract. For a plant whose cycle times reveal its process, this matters as much as any firewall rule.

“Security” is a narrow reason to refuse. Article 4(2) lets users and data holders restrict access contractually only where it could undermine security requirements laid down by law, “resulting in a serious adverse effect on the health, safety or security of natural persons”. A data holder that refuses on this ground must notify the competent authority. The FAQ adds that data must be made available securely, with mechanisms aligned to “relevant legal frameworks, such as those related to cybersecurity”.

Switching provider adds a supplier. Article 5 lets you have the data shared with a third party, and the FAQ expects “more competition for value-added services (e.g. predictive maintenance)”. Every new recipient is a new direct supplier under Article 21(2)(d), so assess it and add it to the register before the data starts flowing. One open point: the FAQ’s test for a “related service” needs a two-way data exchange that affects the product’s functions, and it excludes analytics and “regular repair and maintenance”. A read-only dashboard may therefore fall outside the related-service rules, while a service that pushes parameter changes is more likely inside them. The product-data rights apply either way.

Who Owns Which Risk

For the board, the short answer is that the decision to connect stays with you. Article 20(1) of the Directive requires management bodies to “approve the cybersecurity risk-management measures” taken to comply with Article 21 and to oversee their implementation. A contract can move work to the builder. On our reading, the Article 21 duty stays with your entity.

Party Binding source Risk it owns
You, the operator NIS2 Articles 20 and 21, through national law Deciding to connect, segmentation, access approval, the supplier file, residual-risk acceptance
Builder as machinery manufacturer Machinery Regulation (EU) 2023/1230, Annex III point 1.1.9, from 20 January 2027 A remote device connection must not lead to a hazardous situation; safety-critical software protected; interventions logged
Builder as data holder Data Act Articles 3 to 5 Data access by design, limits on its own use, trade-secret handling
Independent maintenance provider you bring in Data Act Article 5 as recipient; your supplier under Article 21(2)(d) Whatever your contract assigns; you own the supplier assessment

Point 1.1.9 of the Machinery Regulation requires machinery to be designed so that a connection “via any remote device that communicates with the machinery” does not lead to a hazardous situation. It also requires the machine to “collect evidence of a legitimate or illegitimate intervention” in its software or configuration. The Regulation applies from 20 January 2027, so in general it reaches machines placed on the market from then on, not the installed base. Software and connected components may also fall under the Cyber Resilience Act; see our CRA compliance guide.

One question is still open. Article 6(39) of the Directive defines a managed service provider as an entity providing installation, management, operation or maintenance of ICT products or network and information systems “via assistance or active administration carried out either on customers’ premises or remotely”. A builder that remotely administers your controllers may meet that wording. If it does and is in scope, the Implementing Regulation binds it directly. Whether a given remote service meets that wording is a case-by-case question, so ask the builder how it classifies itself.

Gap Check: Seven Steps With Effort and Evidence

Step Owner Effort Evidence an auditor can see
1. List every maker-connected machine, gateway and cloud service OT security lead Medium Supplier registry entries (point 5.2), updated network diagram
2. Classify channels 1 to 3 for each machine OT lead with the builder Low Builder’s written answer on write capability
3. Move gateways into their own zone behind the DMZ Network team High Firewall rule set, allowed endpoints
4. Time-limit the command and session channels OT lead Medium Access request log with start and expiry
5. Unique gateway credentials, named technician accounts, MFA IT and OT Medium Identity register, MFA configuration
6. Add the 5.1.4 clauses and Data Act use limits at renewal Procurement and legal Medium Signed contract annex
7. Present residual risk to management for approval CISO to the board Low Minutes recording the approval

In practice, for a small plant with two or three connected machines, steps 2 and 7 cost little, step 6 can wait for the next contract renewal, and together they close most of the paper gap. Step 3 is where the money goes, and it is the one to plan into the next shutdown window. The wider ten-measure roadmap for factories is in our NIS2 manufacturing compliance guide.

Frequently Asked Questions

Is an outbound-only IIoT connection acceptable under NIS2?

It can be, if it is truly read-only, goes only to documented endpoints, sits in its own zone and is recorded as a required communication. Outbound-only describes who opens the session, not what can travel back down it, so confirm the gateway cannot write to the controller.

Does Implementing Regulation 2024/2690 apply to manufacturers?

Not as manufacturers. Article 1 limits it to DNS, cloud, data centre, managed service and other digital providers, so a builder that is itself a managed service provider can fall under it. Manufacturers must meet Article 21 of the Directive through national law. The Regulation’s Annex is a useful benchmark for what Article 21 means in practice.

Can the machine builder refuse to give us our data for security reasons?

Only in narrow cases. Article 4(2) of the Data Act allows a restriction where access could undermine security requirements laid down by law and cause a serious adverse effect on people’s health, safety or security. A data holder that refuses on that ground must notify the competent authority.

Is the machine builder a managed service provider under NIS2?

Possibly, if it actively administers your systems remotely; the Article 6(39) definition covers maintenance “via assistance or active administration” carried out remotely. Whether that captures a given builder’s remote service is a case-by-case question, so ask the builder how it classifies itself and check its own NIS2 registration.

This article provides general information only and does not constitute legal or regulatory advice. Requirements may vary by jurisdiction and organisation type. Consult a qualified legal professional or compliance specialist for advice specific to your situation.

Sources

  1. European Parliament and Council. Directive (EU) 2022/2555 (NIS2), Articles 6(1), 6(39), 20(1) and 21, Annex II. Official Journal L 333, 27.12.2022.
  2. European Commission. Implementing Regulation (EU) 2024/2690, Articles 1 and 2, Annex points 5.1, 5.2, 6.7, 6.8 and 11.
  3. European Parliament and Council. Regulation (EU) 2023/2854 (Data Act), Articles 3, 4, 5 and 50.
  4. European Commission. Frequently Asked Questions on the Data Act, version 1.4, 22 January 2026.
  5. European Parliament and Council. Regulation (EU) 2023/1230 (Machinery Regulation), consolidated text of 27 July 2026, Article 54 and Annex III point 1.1.9.
  6. NIST. Special Publication 800-82 Revision 3, Guide to Operational Technology (OT) Security, September 2023, sections 5.3.7, 5.4.2 and 6.2.10.
  7. ENISA. Technical Implementation Guidance on cybersecurity risk management measures, version 1.0, June 2025, target audience note and guidance on Annex point 6.7.
Free Download

Get the NIS2 Article 21 Compliance Checklist

90+ assessment items mapped to CIR 2024/2690 — instant PDF, no payment.

✓ Check your inbox — the PDF is on its way.

Don't miss: