Point 13.3.2 of Commission Implementing Regulation (EU) 2024/2690 sets four physical access duties: security perimeters drawn from your risk assessment, entry controls at access points, physical security “for offices, rooms and facilities”, and continuous monitoring of “their premises for unauthorised physical access”. Two things about that list matter more than they look. It names offices, not server halls. And unlike the utility and environmental-threat points before it, it carries no “where appropriate”, so you cannot document your way out of it the way you can elsewhere in the Annex.

Most writing on NIS2 physical security is about data centres, and we have covered that ground in our guide to data centre physical security under CIR Annex 13. This article covers everything else a physical security policy has to reach: head office and branch sites, the comms cupboard nobody locks, laptops on trains, backups in a second building, colocation cages you do not control, and the evidence an assessor will ask for at each one.

This article provides general information only and does not constitute legal or regulatory advice. Requirements may vary by jurisdiction and organisation type. Consult a qualified legal professional or compliance specialist for advice specific to your situation.

Who this applies to, and where physical security sits in NIS2

In plain terms: NIS2 has no separate “physical security” measure. It folds the physical environment into all of its risk-management measures, and the implementing regulation then spells out what that means for eleven types of digital provider.

Free Download

Get the NIS2 Article 21 Compliance Checklist

90+ assessment items mapped to CIR 2024/2690 — instant PDF, no payment.

✓ Check your inbox — the PDF is on its way.

Article 21(2) of the Directive says the measures “shall be based on an all-hazards approach that aims to protect network and information systems and the physical environment of those systems from incidents”. None of the ten lettered points (a) to (j) is about physical security. The familiar hazard list of theft, fire, flood, power failure and unauthorised physical access comes from Recital 79, which explains intent but creates no obligation of its own. The binding detail sits in Annex chapter 13 of Regulation 2024/2690, headed “Environmental and physical security (Article 21(2), points (c), (e) and (i))”. Each of its three sections borrows a different measure: 13.1 business continuity, 13.2 system acquisition, development and maintenance, 13.3 access control.

Your situation What sets your physical security requirements How binding
DNS, TLD registry, cloud, data centre, CDN, MSP, MSSP, online marketplace, search engine, social network or trust service provider (Article 1 of Regulation 2024/2690) Annex chapter 13, plus the physical clauses scattered through chapters 3, 4, 11 and 12 Directly applicable in every Member State, no transposition needed
Any other essential or important entity Your national law transposing Article 21; the Annex is the most detailed EU reference point Binding through national law; national wording may be looser
Supplier to a covered entity Your customer’s contract terms and site-access rules Contractual

National drafting can differ from the Annex. Ireland’s National Cyber Security Centre draft guidance (June 2025) lists “appropriate physical access control measures” as a foundation action it expects every entity to take, but lists physical security for offices and continuous premises monitoring as supporting actions chosen by risk. For the eleven provider types, the same two items are unqualified obligations. For breaches of Article 21, Member States must set maximum fines of at least EUR 10 million or 2% of worldwide annual turnover for essential entities, and EUR 7 million or 1.4% for important entities, whichever is higher (Article 34(4) and (5)).

What Annex 13 requires, point by point, and which parts you can reason away

In plain terms: utility and environmental protections can be scaled to your risk, with a written reason for anything you skip. Perimeter and physical access control cannot be skipped, and neither can testing and review.

Article 2(2) of the Regulation sets the rule. Where the Annex says “where appropriate”, “where applicable” or “to the extent feasible” and you decide a requirement does not fit, you “shall in a comprehensible manner document [your] reasoning to that effect”. Where the Annex says only “shall”, there is no such route. Of chapter 13’s nine numbered points, four have no qualifier at all. In the three test-and-review points, the qualifier attaches only to “update”. Testing and reviewing are always required.

Point Requirement (summarised) Qualifier What it means outside the data centre
13.1.1–13.1.2 Prevent loss or interruption from failed supporting utilities: electricity, telecoms, water, gas, sewage, ventilation and air conditioning; redundancy; emergency-supply contracts; protect power and telecom lines “against interception and damage” 13.1.2 “where appropriate” A UPS for the comms room, a second ISP line where an outage stops the service, cabling that is not exposed in shared areas
13.2.1–13.2.2 Prevent or reduce the effects of physical and environmental threats, based on the point 2.1 risk assessment; set minimum and maximum control thresholds; monitor and report breaches of them 13.2.2 “where appropriate” A temperature and water-leak sensor in the network room, with alerts going to a named person
13.3.1 Prevent and monitor unauthorised physical access, damage and interference None Applies to every site that houses network and information systems
13.3.2(a)–(d) Security perimeters set by the risk assessment; entry controls at access points; physical security “for offices, rooms and facilities”; continuous monitoring of premises None Locked, controlled entry for offices and comms rooms, with continuous monitoring
13.1.3, 13.2.3, 13.3.3 Test and review “on a regular basis or following significant incidents or significant changes to operations or risks” Only “update” is qualified A dated test record for each site, plus a review after a move, refit or break-in

All three chapter 13 review points say “on a regular basis”, where most of the Annex says “at planned intervals” (the only other use is crisis-management point 4.3.4). That wording gives you more room, but you still need a written test calendar to show the regularity. Risk sets how strong each measure is, not whether you have one. Point 13.3.2(a) ties the perimeter to the risk assessment, so a five-person branch office can justify a keypad door and an alarm where head office has turnstiles. It cannot justify nothing.

Five places outside the data centre your policy has to reach

In plain terms: anywhere your systems or their data physically are counts as a facility. That includes places you do not own.

The ENISA glossary in its Technical Implementation Guidance (June 2025) defines facilities as “the physical location housing the entity’s network and information systems”. Its examples of evidence for 13.2.1 ask for a risk assessment that identifies “physical locations, such as data centres, offices and server rooms” and maps critical assets to them. In practice that list is longer than most policies admit.

Location Annex points that reach it Minimum the policy should state
Offices and branch sites 13.3.2(b)–(d); 11.1.2(a) on access by “staff, visitors, and external entities such as suppliers and service providers” Controlled entry, visitor sign-in and escort, visible ID, alarm or monitored access outside hours
Comms rooms and network cupboards 13.3.2(a); 13.1.2(c) on lines “against interception and damage”; 13.2.2 Locked room with a named access list, power protection, environmental sensor, no shared use as a store room
Home and mobile working 13.3.1; 12.2.2 on “safe storage, safe transport”; ENISA footnote 109 Rules for locking devices away, travel handling, and reporting loss
Colocation and cloud facilities 13.3 via the supplier; chapter 5 supply chain Contract clauses on physical access, plus a right to see audit reports
Backup storage and media 4.2.2(c)–(d); 12.3 removable media; 12.2.2 disposal Physical access control for backup copies by classification level, media rules, destruction records

Two of these need more than a table row.

Colocation and cloud. You cannot inspect a hyperscaler’s data hall, and the regulation does not expect you to. ENISA’s footnote 109 says that where “third-party cloud or co-location facilities are used, physical access controls should be reviewed and enforced contractually through SLAs and verified via audit reports (e.g. ISO 27001, SOC 2)”. Your policy should say that, name who reviews the reports each year, and say what happens if a report shows an exception.

Fully remote organisations. ENISA’s footnote 109 accepts that badge systems, mantraps and on-site guards “may not be applicable” where there is no central office or on-premises infrastructure, and footnotes 107 and 108 make similar allowances for central utility and environmental protections. The focus shifts to MFA, endpoint compliance and guidance on securing home workspaces. That changes how you meet 13.3. It does not remove the duty. Our remote and hybrid work compliance guide covers the home-office side in detail.

“Continuously monitor” without breaking GDPR

In plain terms: continuous means monitoring that runs all the time without someone having to switch it on. It does not have to mean keeping weeks of CCTV footage, and under data protection rules it usually should not.

Point 13.3.2(d) is unqualified, so every in-scope site needs some form of continuous monitoring for unauthorised entry. ENISA’s suggested measures include CCTV, electronic entry control “with an audit trail”, and “guards and/or alarms to monitor every physical access point … 24 hours per day, seven days per week”. In our reading, a monitored intruder alarm combined with logged badge entry meets the “continuous” test for a small office without any camera. That is our interpretation, not settled guidance, so record the reasoning in the policy.

Where you do use cameras, ENISA says to retain recordings “for a defined period, in accordance with the GDPR”. The European Data Protection Board’s Guidelines 3/2019 on video devices are direct on this point (paragraph 121). Footage should “in most cases” be erased “after a few days”, and storage beyond 72 hours needs more justification of purpose and necessity. Some Member States have their own rules on storage periods. The data-centre retention periods sometimes quoted in practice do not carry over to an ordinary office, where the risk case for keeping footage is weaker. Entry-log retention is a separate question: point 3.2.3(i) lists “physical access to facilities” among the logs to keep where appropriate, and that retention belongs in your logging policy.

Point 13.2.2(b) also asks for “minimum and maximum control thresholds”. Outside a data centre this is usually small: a comms-room temperature band, a humidity ceiling and a water-leak alarm, each with a named person who receives the alert. Write the numbers down. A sensor nobody configured thresholds for is not evidence of anything.

How to structure the policy, section by section

In plain terms: one topic-specific policy covering every site type, written under your top-level security policy and owned by named people.

ENISA suggests “creating a topic-specific policy for protection against physical and environmental threats”, and its evidence examples ask for a “description of facilities and network and information systems in scope”. The policy then sits in the topic-policy register beneath your top-level IT security policy. A structure that covers the chapter and the clauses outside it:

Section Annex anchor Owner Effort
1. Scope and site register (every location housing systems or data) 13.2.1; ENISA evidence examples CISO Low
2. Site classification and security perimeters 13.3.2(a); point 2.1 risk assessment CISO with facilities Medium
3. Entry controls, ID and visitors 13.3.2(b); 11.1.2(a) Facilities Medium
4. Office, room and comms-room security 13.3.2(c) Facilities and IT Medium
5. Monitoring, alarms and log retention 13.3.2(d); 3.2.3(i) and (l) IT security, with the DPO for CCTV Medium
6. Utilities and environmental thresholds 13.1; 13.2.2 Facilities Medium to high
7. Off-site working, colocation and cloud 12.2.2; ENISA footnote 109; chapter 5 CISO and procurement Low
8. Equipment, media, backups and disposal 12.2.2; 12.3; 4.2.2(d) IT Medium
9. Physical access rights: grant, review, revoke 11.1.1; 12.5; ENISA 13.3.2 guidance HR and facilities Low
10. Documented reasoning for qualified points not applied Article 2(2) Compliance Low
11. Testing and review calendar 13.1.3, 13.2.3, 13.3.3 CISO Low

Section 9 is where physical and logical controls meet. ENISA asks that physical access control be “integrated with logical and network access control, in line with human resources security procedures”, so physical rights should follow the same joiner, mover and leaver process as your logical access control policy. It also asks for a designated official who approves the list of people with physical access. The departure checklist under point 12.5 should return badges and keys alongside laptops; the asset management inventory is where those items should already be listed. For section 11, ENISA suggests “quarterly fire drills and annual assessments of physical security measures”, including unannounced tests.

Each role starts from a different point. A CISO should start with section 1, because every later section depends on the site register. An SME owner can usually meet sections 3, 4 and 9 in a week with a locked comms cupboard, a visitor book and a badge-return step in offboarding. A compliance officer should write section 10 first: the reasoning record is the document an assessor cannot infer from walking the building.

The ISO 27001 crosswalk: five physical controls ENISA never maps

In plain terms: if you hold ISO 27001, your Annex A physical controls carry most of chapter 13. They do not line up neatly, and the gaps are in exactly the off-site areas this article covers.

ISO/IEC 27001:2022 has fourteen physical controls, A.7.1 to A.7.14. We parsed ENISA’s mapping table (version 1.2) to see where each one lands:

ISO 27001:2022 control CIR point ENISA maps it to
A.7.1 Physical security perimeters; A.7.4 Physical security monitoring 13.3
A.7.2 Physical entry 13.3 and 11.1
A.7.3 Securing offices, rooms and facilities; A.7.5 Protecting against physical and environmental threats 13.2
A.7.11 Supporting utilities 13.1
A.7.7 Clear desk and clear screen 12.3
A.7.10 Storage media 12.2 and 12.3
A.7.13 Equipment maintenance 6.4
A.7.6 Working in secure areas; A.7.8 Equipment siting and protection; A.7.9 Security of assets off-premises; A.7.12 Cabling security; A.7.14 Secure disposal or re-use of equipment Not mapped anywhere in the table

Two findings matter for your policy. First, the unmapped controls are not irrelevant to the Regulation. Point 12.2.2 covers “safe transport” and “destruction” of assets, close to A.7.9 and A.7.14, and point 13.1.2(c) protects telecom lines against interception, close to A.7.12. The mapping table is advisory, so this is a gap in the crosswalk, not in your obligations. Do not drop those controls from scope because the table skips them. Second, the word “clear” does not appear anywhere in the Annex, so a clear-desk rule is good practice rather than a named requirement. ENISA files A.7.7 under removable media. Third, ENISA maps A.7.3, “Securing offices, rooms and facilities”, to 13.2, even though that exact phrase appears in 13.3.2(c). If you cite A.7.3 as your evidence for office security, cite it against both points.

Evidence an assessor will ask for

Drawn from ENISA’s examples of evidence for chapter 13 and the related points, the file for each site should hold:

  1. The approved physical security policy with its site register and in-scope systems.
  2. A risk assessment that names each location and maps critical assets to it.
  3. Perimeter and zone definitions per site, linked to that assessment.
  4. An up-to-date list of people with physical access, signed off by the designated official.
  5. Entry-system logs and visitor records for the retention period your policy sets.
  6. Defined environmental thresholds and records of any breach, with the alert sent and action taken.
  7. Utility protection records: UPS and generator test results and emergency-supply contracts, where applied.
  8. Physical access controls for backup copies held at a second location, matched to their classification (point 4.2.2(d)); see backup and recovery requirements.
  9. Colocation and cloud audit reports, with a note of who reviewed them and when.
  10. Dated test results: drills, intrusion tests, and checks for unauthorised removal of equipment at site exits.
  11. The Article 2(2) reasoning record for every qualified point you chose not to apply.
  12. Offboarding records showing badges and keys returned under point 12.5.

In our experience item 11 is the one missing most often, usually because nobody realised a written reason was required. It is also the cheapest item to produce.

Frequently asked questions

Does a company with no server room still need a physical security policy?
Yes, if it is a covered entity. Point 13.3.1 is about unauthorised access to network and information systems wherever they are. Offices with laptops, a network switch and a printer are facilities in ENISA’s definition. For a fully remote company, ENISA expects the policy to shift to device handling, home-workspace guidance and supplier assurance rather than disappear.

Is CCTV mandatory under NIS2?
No. Point 13.3.2(d) requires continuous monitoring of premises, and CCTV is one option in ENISA’s list alongside alarms, guards and electronic entry logs. If you use cameras, the GDPR sets the retention limits.

Can one policy cover physical security for the data centre and the offices?
Yes, and a single policy with a site register is easier to keep current. Classify each site and set controls per class. The data centre will sit at the top of the scale, with requirements covered in our data-centre guide.

How often must physical security measures be tested?
The Annex says “on a regular basis” and after significant incidents or significant changes. It sets no interval. ENISA’s suggestion of quarterly fire drills and an annual assessment is a reasonable floor to write into your calendar.

Sources

  • Commission Implementing Regulation (EU) 2024/2690, EUR-Lex: Articles 1, 2(2) and 16; Annex points 3.2.3, 4.2.2, 11.1.1–11.1.2, 12.2.2, 12.3, 12.5 and chapter 13.
  • Directive (EU) 2022/2555 (NIS2), EUR-Lex: Recital 79 and Article 34(4)–(5).
  • Directive (EU) 2022/2555, Article 21(2), via nis-2-directive.com: the all-hazards chapeau and points (a)–(j).
  • ENISA, Technical Implementation Guidance on Regulation 2024/2690, version 1.0, June 2025: guidance, examples of evidence and footnotes 107–109 for chapter 13; glossary definition of “facilities”. Non-binding.
  • ENISA, Technical Implementation Guidance mapping table, version 1.2 (21 August 2025): CIR-to-ISO/IEC 27001:2022 mapping. Advisory.
  • Advisera, ISO 27001:2022 Annex A physical controls 7.1–7.14: control titles.
  • National Cyber Security Centre Ireland, NIS 2 Risk Management Measures Guidance, draft of 4 June 2025: RMM010 foundation and supporting actions. Draft guidance.
  • European Data Protection Board, Guidelines 3/2019 on processing of personal data through video devices, version 2.0, adopted 29 January 2020: paragraphs 120–121 on storage periods.

Verification note: quoted provisions were checked against the official English text of Regulation 2024/2690 and Directive 2022/2555. The ISO crosswalk was computed from ENISA’s published mapping table. ENISA, NCSC Ireland and EDPB material is guidance and is labelled as such.

Free Download

Get the NIS2 Article 21 Compliance Checklist

90+ assessment items mapped to CIR 2024/2690 — instant PDF, no payment.

✓ Check your inbox — the PDF is on its way.